This machine has several technical functions and can be used in medical, food and chemical industry..
Functions:
- Granulation of a powder and coating;
- Possibility of production of particles 50µm and coating;
- Manufacture of granules of round type and coating;
- Powder drying;
- Multifunctional performance.
Technical parameters
Model |
||||||||||||
Name |
unit |
1 |
3 |
5 | 10 | 15 | 30 | 60 | 120 | |||
Diameter |
mm |
300 |
400 |
600 | 700 | 800 | 1000 | 1200 | 1500 | |||
Output |
kg/batch |
0.3- |
1.5- |
4- | 8- | 10- | 20- | 30- | 60- | |||
1.5 |
4.5 |
6 | 15 | 20 | 40 | 60 | 120 | |||||
Ventilator power |
kW |
2.2 |
3 |
4 | 5.5 | 7.5 | 7.5 | 11 | 18.5 | |||
Steam |
Pressure | MPa |
0.4-0.6 |
|||||||||
Consumption | kg/h | 3kW |
6kW |
20 |
35 | 42 | 60 | 160 | 240 | |||
Compress air |
Pressure | MPa |
0.6 |
|||||||||
Consumption | m3/min |
0.3 |
0.3 |
0.4 | 0.6 | 0.6 | 0.9 | 1.1 | 1.5 | |||
Overall dimensions |
A | mm |
1950 |
1680 |
2200 | 2500 | 2800 | 2850 | 3300 | 3500 | ||
B | mm |
750 |
1100 |
1200 | 1750 | 1950 | 2150 | 2300 | 2550 | |||
C | mm |
1100 |
850 |
1800 | 2150 | 2700 | 3000 | 3600 | 4200 | |||
Noise level |
dB |
when isolated ventilator ≤75 |